Top information

Testing of Concrete Blocks - Know More

DETERMINATION OF BLOCK DENSITY Three blocks shall be dried to constant mass in a suitable oven heated to approximately 1000C After cooling the blocks to room temperature, the dimensions of each block shall be measured in centimeters to the nearest millimeter and the overall volume computed in cubic centimeters...

Reinforced Concrete Analysis and Design - Know More

02-09-2011 0183 32 218 Shear area Design of Reinforced Concrete Beams 47 02 Shear area of concrete = 08Ac where = gross cross-sectional area of concrete Note The shear area of concrete is entered as input to some computer programs when the analysis is required to take into account the deformations due to shear 219 Thermal strain...

Section properties - Know More

31 General All section properties have been accurately calculated and rounded to three significant figur They have been calculated from the metric dimensions given in the appropriate standards see Section 11 For angles, BS EN 10056-1 assumes that the toe radius equals half the root radius 32 Sections other than hollow sections 321 Second moment of area I...

Part II Review Unit Review Name Work Energy Power - Know More

14-01-2018 0183 32 37The total work done in lifting a typical high school physics textbook a vertical distance of 010 meter is approximately A 1700 W B 340 W C 180 W D 70 W 38What is the rate at which work is done in lifting a 35-kilogram object vertically at a constant speed of 50 meters per second? A 80 J B 120 J C 240 J D 480 J...

RC Element Design Spreadsheet to BS 8110 - Know More

RC Element Design Spreadsheet to BS 8110 Description This is an RC Spreadsheet Power Pack It contains five spreadsheets for designing RC elements like columns, beams and slabs It also includes column chart generator In essence this package covers all main elements in a reinforced concrete structure, making this a very powerful tool ....

What is a Fire Rated Wall? - Know More

03-11-2020 0183 32 In Type II or V construction, walls shall be permitted to have a 2-hour fire-resistance rating b For Group H-1, H-2 or H-3 buildings, also see Sections 4157 and 4158 For example when looking at the above Table, a Fire Wall separating a Group S-2 occupancy will require a 2 hour fire rated wall This rating is expressed in hours and it is ....

Physical Resource Block - Know More

One physical resource block PRB spans 12 subcarriers, which with the 15-kHz subcarrier spacing correspond to 180 kHz When full-PRB transmission is used, the smallest time-frequency resource that can be scheduled to a device is one PRB pair mapped over two slots, which for the normal CP length case with 7 OFDM symbols per slot corresponds to 12 subcarriers over 14 ,...

British Standards and other approved documents used in , - Know More

British Standards and other approved documents used in Paving, Drainage and Landscaping projects Pavingexpert is an approved BSI Affiliate, and so you can purchase standards and other documents via this page by clicking the link on each listed item...

Minimum Electrical Clearance Electrical Notes Articles - Know More

22-04-2011 0183 32 Minimum Electrical Clearance As Per BS 162 INDOOR Voltage in KV Phase to earth in mm Phase to phase in mm 0415 158 1905 0600 1905 1905 33 508 508 66 635 889 11 762 1270 15 1016 1651 22 1397 2413 33 22225 3556 Minimum Electrical Clearance As Per BS 162 OUTDOOR Voltage in KV Phase,...

STANDARD SPECIFICATIONS FOR CONSTRUCTION WORKS 2008 - Know More

Aerated concrete blocks shall comply with BS EN 771 Part 4 with a minimum compressive strength of 5 N/mm2 unless otherwise stated Decorative blocks shall comply with drawings and BS EN 771 Part 3 Non load-bearing block work includes special purpose block work such as thermally insulated external wall rendered system...

Labour Requirement Output Per Day For Different Civil Works - Know More

In a project budget, the toughest thing is to identify the source of material and required manpower calculation We have to deploy adequate manpower to complete a certain activity without any chaos In this post, we had listed out the approx labour requirement for civil works and also Labour output per day for different works In the earlier post, we had seen the material ,...

Standard Specifications of Hollow and Solid Concrete Blocks - Know More

🕑 Reading time 1 minute In recent times, we have seen a drastic transition from brick masonry to concrete block masonry due to its numerous advantages such as fire resistance, good acoustic performance, cost-efficiency, and strength In this article, we ll discuss the standard specifications of hollow and solid concrete blocks such as dimensions, classification, ,...

4 Masonry elements - Know More

42 Symbols Those symbols used in BS 5628 that are relevant to this manual are as follows A horizontal cross-sectional area b width of column e x f k G k g A g d h h ef K L l ef Q k t t ef t p t 1 eccentricity at top of a wall characteristic compressive strength of masonry characteristic dead load design vertical load per unit area design ....

Reinforced Concrete Analysis and Design - Know More

03-09-2011 0183 32 Minimum area of reinforcement at top of slab , Loading per unit area used in yield-line analysis kN/m2 Ultimate loading per unit area Restraint factor for computation of early thermal cracking , Continuous le = 10 Cantilever where 10 3112 Moment of inertia...

SBC Of Soil Safe Bearing Capacity Of Soil Minimum SBC , - Know More

Safe Bearing Capacity has the following significance regarding the soil, The Soil tends to deform when stressed due to loadingThe soil deformation depends upon factors like water content, bulk density, angle of internal friction, and the manner in which load is applied on the soil The Soil properties like density shear strength permeability etc, affect the bearing capacity of the soil...

What is the minimum percentage of steel in slabs , - Know More

Answer 1 of 17 As per IS 456 2000 In SLAB as per Clause 26521 Min reinforcement shall be 015 of total cross-sectional area for mild steel bars and 012 of total cross-sectional area for HYSD bars In BEAM as per clause 26511 min tension reinforcement shall be ,...

Masonry design guide - Know More

ie, actual block length or height Tables 6 to 9 enable the vertical and horizontal co-ordination of 390 x 190mm and 440 x 215mm block face sizes to be set out at the design stage Step 2 From the selected co-ordination factor column, find the required blockwork dimension and then read off the related number of blocks...

CONCRETE BLOCK MASONRY - Know More

Introduction These are the concrete blocks either hollow or sol A hollow unit is that unit which has core void area greater than 25 of the gross area They may be used for both load bearing as well as non load bearing walls...

AAC blocks specifications - Know More

AAC blocks AAC block is a special type of concrete block made up of fine aggregates, Portland cement, water, and another expansion agent Aluminum powder AAC block was developed in 1924 by a Swedish architect AAC block is alternate materials for building materials that have similar properties as wood...

Calculating the Amount of Work Done by Forces - Know More

When done, click the button to view the answers 1 Apply the work equation to determine the amount of work done by the applied force in each of the three situations described below See Answer Diagram A Answer W = 100 N 5 m cos 0 degrees = 500 J...

REINFORCED CONCRETE DESIGN TO EC2 - Know More

- Minimum Reinforcement Area - Control of Cracking without Direct Calculation - Table 72N Maximum bar spacing for crack control - Table 73N Maximum bar diameters for crack control 100 MOMENT AND SHEAR COEFFICIENT FOR CONTINUOUS BEAM 17 - Table 35 Moments and shear coefficients of continuous beam Ref BS 8110 Part 1 1997...

Minimum and maximum area of steel required in rcc slab as , - Know More

10-06-2014 0183 32 The minimum area of steel required in RCC slab as per BS code is 012 to 015 of total area The maximum diameter of bar in slab, shall not exceed D/8, where D is the total thickness of slab...

Method Statement for Blockworks/Masonry - Know More

10-05-2018 0183 32 f Blocks not exceeding 75 mm thickness shall be sol g Fire rated concrete block of size 15 mm x 400 mm x 200 mm shall be fire resistant up to 120 min 5 Wall ties and metal lath for block wall stiffeners See TDS samples in pdf of commercially available wall ties and metal lath Wall Ties-block wall stiffeners for Blockworks and Expanded Mesh_Lath-block wall ,...

Reinforced Concrete Design to BS8110 Structural Design 1 , - Know More

min = 2 For High Yield Steel r min = 3 OR 4 for gt =25 mm r r For 90 bend L A = 4r < 12 For Hook L A = 8r < 24 46 Laps In Reinforcement To enable continuity of reinforcement at construction joints and to enable bar lengths to be man-handled lapped bars are normally detailed Min lap length >15 OR 300 mm...

Thrust Block Design Theory and Worked , - Know More

Thrust Block Design Example The following assumptions and design data were considered in the analysis and design Density of concrete 24 kN/m 3 Grade of the concrete of grade 25 Minimum characteristic strength of steel 460 N/mm 2 Cover to the reinforcement below the ground level 75mm...

Timber Strength Calculations - Know More

BS 5268-2 2002 Structural use of timber Part 2 Code of practice for permissible stress design, materials and workmanship BS EN 1912 2004 Structural timber Strength classes- Assignment of visual grades and species BS 4978 1996 Specification of Softwood Grades for Structural Use...

No.416 Jianye Road, South Jinqiao Area,Pudong New Area, Shanghai, China.

Telephone : +86-21-58386189, 58386176

FAX : +86-21-58385681